Westinghouse 25MW 60 Hz Condensing turbine for sale


Qty
Item #
Westinghouse 25 MW 60 Hz
Description
Images
Downloads

Description

Westinghouse Canada Ltd. - Turbine & Gen Division, Hamilton, Ontario Equipment List, please click for details One 25000 KW 3600 RPM Steam Turbine

Description

 Westinghouse Canada Ltd. - Turbine & Gen Division, Hamilton, Ontario

Equipment List

One 25000 KW 3600 RPM Steam Turbine
One Lube Oil Consol
One Set of Station Equipment including Oil Purifier, Coolers, etc.
One 29411 KVA 360 RPM Turbo Generator
One Gas System Equipment and Interconnecting Piping
One Seal Oil System Equipment
Nameplate for Hydrogen Panel
One Hydrogen Panel
One Static Generator Excitation Unit
One Bus Trough
One Generator Neutral Grounding Cubicle
One Generator Phase Terminal Cubicle

Rating Data:

Generator - 29,411 KVA, 25,000 KW, - 95 P.F., 30 PSIG H2 Pressure, 1231
Stator Amps, 13,800 stator volts, 22,000 Rated KVAR lagging at 30 PSIG of H2
250 Exciter Volts, 3-phase, 60 cycle, 3600 RPM, frame 2-66 x 80. Maximum
inlet Water Temperature 100°F (38°C).

Direct Axis Synchronous Reactance 172%
Direct Axis Synchronous Reactance 15%

Zero Sequence Reactance 4.30%
Rated Load Excitation Volts 220 - Amps 472
Normal Exciter Response: with 5% error signal 1.0
Shirt Circuit Ration:  0.64
Rated Load at 0.5 psig H2 pressure 27060 KVA / 15 psig H2 pressure 23530 KVA
Static Volume of generator gas space 900 cu. Ft
Quantity of CO2 required to purge generator of air
At standstill: 1340 cu. Ft.
At normal speed: 1800 cu. Ft.
Quantity of Co2 required to purge generator of H2
At standstill: 1800 Cu. Ft.
At normal speed 2700 cu. ft.
Estimated H2 make-up per day 75 cu. Ft. at 0.5 PSIG H2 pressure / 225 cu.
Ft. at 30 PSIG H2 pressure
Cooler Water for H2 coolers 200 US gpm (164 Imperial) with 29,411 KVA load.


HYDROGEN COOLED TURBINE GENERATORS

Generator Identification
Serials (Stators) 1S  -1-S-1620-1 & 1-S-1-S-1630-1
(Rotors) 1R  -1-S-162-2 & 1R-1S-1630-2

Rpm 3600
Phases 3
Cycles 60
Volts 13800

Hydrogen Pressure 0.5 15 30
KVA 23529 27058 29411
Amperes 984 1132 1230
Power Factor 0.85 0.85 0.85

Static Gas Volume of Generator 900 cu. Ft. (25,500 litres)
I.B. No. CG-4498

TURBINE:
Steam Inlet pressure 59.76 Kg./cm2
Steam Inlet Temperature 482.2°C
Exhaust Pressure 6.35 Cem.Hg.Abs.
Extraction Operation: Feedwater Heating 5 Stages

NOT INCLUDED IN SCOPE
Condenser & condensing system