TAURUS 60S 7MW combined cycle plant
please click on images on the right for additional pictures
Used SOLAR TURBINES TAURUS 60S 7 MW Combined cycle plant for
sale
Location
Japan
Japan
2001
Solar Taurus60S 4970kw (Packaged by Mitsui
Zosen)
Natural gas burning with gas compressor.
Maintenance Details:
Manufacturer’s Maintenance : Every year May, Aug, and
December
December
for the boiler, steam turbine, and gas compressor
Absorption
Filter Regular Maintenance (Once a year)
Absorption
Filter Regular Maintenance (Once a year)
The package total about 63,000 hrs
Engine hrs 24,000 since last replacement in 2010
Generator 50Hz(Shinko ),6600kv
GENERATOR PART : SHINKO FSLK-AF-1100 6000KW 6600VO 50HZ 1500 ROPM
4 POLE
3PHASE
MAX. OUT PUT 7480KW
EXITING UNIT OUTPUT 36KW
VOLTAGE 80VOLT
CURRENCY 450AMP
BRUSHLESS EXTING TYPE
EXITING VOLT 50V, CURRENCY
6.5 AMP
YEAR 2000 DEC.
GENERATOR WEIGHT 16.3
TON
GENERATOR SHINKO FSLK-AF-1100 6MW
6600V
HRSG :
10t/h MIURA HEAT RECOVERY BOILER NATURAL CIRCULATION WATER PIPE BOILER(OUT DOOR
TYPE)
MAX. STEAM CAPACITY
10.2 T./HOUR
MAX. USING
PRESSURE 2,350 KPA (GAGE PRESSURE)
MAX. .USING TEMPERATURE 425
DEG.C (HEATER)
TYPE)
MAX. STEAM CAPACITY
10.2 T./HOUR
MAX. USING
PRESSURE 2,350 KPA (GAGE PRESSURE)
MAX. .USING TEMPERATURE 425
DEG.C (HEATER)
253 DEG.C(STEAM
UNIT,
UNIT,
Steam turbine generator
1940kw( Alsthom)
MITSUI ALSTOM STEAM TURBINE CD3.7
1970KW (O DEG.C)
1970KW (O DEG.C)
MAIN INLET PRESSURE
1.86 MPA(GAGE PRESSURE)
MAIN
INLET TEMPERATURE 345DEG.C
EXHAUST PRESSURE 4.9KPaA(FIXED
PRESURE)
RPM 10920 RPM
FIRST CRITICAL SPEED 4300 RPM
2ND CRITICAL SPEED 21000
RPM
TURING DIRECTION CLOCK
TURN FROM HIGH PRESSURE
PRODUCTION YEAR 2001 MAY
WEIGHT 5000 KGS
1.86 MPA(GAGE PRESSURE)
MAIN
INLET TEMPERATURE 345DEG.C
EXHAUST PRESSURE 4.9KPaA(FIXED
PRESURE)
RPM 10920 RPM
FIRST CRITICAL SPEED 4300 RPM
2ND CRITICAL SPEED 21000
RPM
TURING DIRECTION CLOCK
TURN FROM HIGH PRESSURE
PRODUCTION YEAR 2001 MAY
WEIGHT 5000 KGS
Gas Booster
compressor.
compressor.
GAS COMPRESSOR
HOWDEN NO. JOO595
HYDRAULIC
TEST PRESSURE 42. BAR.G
MAX.
WORKING PRESSURE HIGH SIDE 24.1 BAR.G
LOW
SIDE 5.5 BAR.G
MAX.
SPEED 4500 RPM
HOWDEN NO. JOO595
HYDRAULIC
TEST PRESSURE 42. BAR.G
MAX.
WORKING PRESSURE HIGH SIDE 24.1 BAR.G
LOW
SIDE 5.5 BAR.G
MAX.
SPEED 4500 RPM
Absorption chiller for GT intake air
cooling
cooling